Introduction
Fringe stopping is a technique for implementing geometric corrections for an observation in the correlator, prior to cross-correlation, integration and averaging. It is an alternative to performing geometric corrections later in the data processing pipeline, with tools such as Birli or cotter, as has been necessary for MWA observations in the past. In most cases fringe stopping is expected to be superior to traditional post-correlation geometric corrections, and it will be the default mode for MWA observations starting in the second half of 2023. It is currently available for evaluation by request, and feedback is especially welcome at this stage in the commissioning process.
Background
The fringe stopping process involves applying virtual signal delays to compensate for varying path delays between tiles during an observation. The major advantage of this approach to geometric corrections is that it is performed prior to cross-correlation, integration and averaging. Prior to fringe stopping, many of the observation modes available to MWA users involving long integration times or broad frequency averaging would have resulted in unacceptable geometric errors, as downstream processing tools require relatively fine-grained data to perform corrections effectively - especially at longer baselines, where the rate of fringe rotation is higher. Short integration times and fine frequency resolution both have a large impact on the size of the visibility data produced in a given observation, without necessarily improving the scientific usefulness of the data - typically, most of this resolution is averaged away in the final data products. Fringe stopping allows users to make use of long integration times and broad frequency averaging, without sacrificing the quality of the data. Smaller data volumes are easier to manage, store and process, and longer observations that may have produced prohibitively large volumes of data in the past may be feasible with fringe stopping.
We encourage all MWA users to test this new capability for any observations in the first observing semester of 2023. Starting in the second observing semester of 2023, fringe stopping will be the default mode for all MWA observations. Observations without fringe stopping will continue to be supported on an opt-out basis.
Implementation
A technical summary of the MWAX fringe stopping implementation will be published soon as part of the forthcoming MWAX paper, a detailed description of the design and validation will be published shortly thereafter.
A (very) brief overview: when a fringe-stopping observation is scheduled, the scheduling software generates an additional data table in the metafits file sent to the correlator, containing periodically updated Az/Al values for each tile, reflecting small changes in pointing direction required during the observation period. These updated pointing directions are calculated at 4-second intervals using the astropy library and picked up where the real-time part of the fringe stopping system begins, during UDP voltage capture. For each Az/Al entry, and for each tile, a path length difference is calculated relative to the array centre, and converted to a time delay. The time delay is interpolated between the 4s reference points at a 5ms granularity, corresponding to the FFT block size in the correlator. The delay is split into a whole-sample and fractional-sample component, the latter of which corresponds to a delay shorter than the sampling period of the coarse-channelised voltage data. The whole-sample component is used to shift actual voltage samples in the data forward or back by an integer number of samples. The fractional component is stored in a metadata table in the voltage capture file, and applied by the correlator after the F-stage, in the frequency domain, as a phase rotation.
The fundamental unit of time for fringe-stopping is the sample, which at a sample rate of 1.28MHz, corresponds to about 0.7 microseconds. Delays are typically in the range of +/- 20 whole samples. The fractional component is represented in the metadata table with 32-bit floats, which we found to be sufficient - targeting a precision on the order of microsample resolution. 16-bit signed integers targeting millisample resolution were found to be insufficiently precise for fringe stopping.
Diagram: Comparison of geometric corrections process for using Birli and fringe-stopping
Usage
Fringe stopping may be requested for any observation in the first observing semester of 2023. Users may request it at the time of scheduling, or at any time prior to the start of the observation.
Validation
Fringe stopping has been validated against the output of Birli and shown to produce identical results in tests involving hand-crafted data, designed to test particular aspects of its behaviour in isolation. Results on real-world data, from running fringe stopping on live observations simultaneously with Birli in a split-mode configuration, have shown fringe-stopping to perform comparably to Birli on short integration times and fine frequency averaging, and with superior results on longer integration times and coarser channel averaging,
The validation process will be described in detail in a future publication.
Diagram: Time-phase plots generated from fringe stopping (left) and Birli (right) data for 20 baselines, observing PicA with an 8s integration time.
Diagram: Time-phase plots for fringe stopping (blue) vs Birli (gold) for five baselines (rows) at increasing integration times (columns, 0.5s, 1s, 2s, 4s, 8s).